General Performance IEC Inlet Filter
General Performance IEC Inlet Filter
IEC Inlet Filter
FN9222R-1-06 IEC Inlet Filter
Filtered IEC Power Entry Module
10 A, 250 VAC
Filtered IEC Power Entry Module
10 A, 250 VAC
4163
IEC Inlet Filter
Maximum continuous operating voltage 250 VAC, 50/60 Hz
Operating frequency dc to 400 Hz
Rated currents 1 to 20 A @ 50°C
Approvals by rated current 1 to 10 A (ENEC, CQC)
16 A (ENEC, CQC) for 16 and 20 A types
1 to 20 A (UL, CSA)
High potential test voltage P –> PE 2000 VAC for 2 sec (standard types)
P –> N 250 VAC for 2 sec (all Z types)
P –> N 1000 VAC for 2 sec (1 to 10 A types, not Z types)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 1100 VDC for 2 sec (16 and 20 A types, not Z
types)
Protection category IP 40 according to IEC 60529
Temperature range (operation and storage) -25°C to +85°C (25/85/21)
Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (X to XX A,
not Z types)
Flammability corresponding to UL 94 V-2 or better
Optional medical versions (B type) according to
IEC/EN 60601-1
Snap-in versions (S and S1 type)
Hot inlet versions (HI type)
Optional overvoltage protection (Z type)